SAV Plus


SAV Plus™ - Control Valve

The SAV Plus™™ is a heavy-duty position control valve that maintains a valve’s position based on a desired % output set point. It is designed to work in applications where the control of a process variable (PV) is accomplished using an independent sensor. Perfect for controlling Dew-point, Carbon Potential, etc.

The SAV Plus™™ incorporates a standard Waukee Flo-Meter™ scaled to the application requirements and an electronic control valve that modulates flow based on an external signal from a control system. The external signal can be 4-20mA or may be delivered using digital communications.

FEATURES

  • Large LCD display provides vital information such as Valve position, Alarms, and diagnostic messages
  • Simple and intuitive programming menus
  • Field programmable engineering units
  • Standard Modbus TCP for easy integration with control systems
  • Manual actuation of valve possible
  • Easy to install
  • Built-in Web Server for remote access to device
  • Calibration in state-of-art ISO/IEC 17025:2005 accredited laboratory


DOWNLOAD BROCHURE
  • Annealing
  • Sintering
  • Neutral hardening
  • Carburizing
  • Additive gas or air for endothermic generators
  • Nitriding and much more
For applications requiring electronic measurement of flow rate, upgrade to our Valve-Tronic Plus™™ control valve which includes a flow sensor.
POWER REQUIREMENTS:500mA @ 24 VDC ±10%
DIGITAL INPUT:1 Input, 24 VDC (programmable)
DIGITAL OUTPUT:3 Outputs, 24 VDC, 1.0A max (programmable)
SETPOINT INPUT SIGNAL:Isolated 4-20mA
SCALE: Air (70°F; 14.7 PSIA / 21°C; 1 bar)
Model S: 4-100 CFH (0-3 m3/hr)
Model M: 10-1500 CFH (0-42 m3/hr)
Model L: 150-18,000 CFH (4-510 m3/hr)

Liquid
Model SF: 0.2-25 GPH (0.75-95 l/hr)

ACCURACY:VDE/VDI 3513 sh.2, qG=50%
Model S/SF: 5%
Model M: 4%
Model L: 3%
MAX OPERATING TEMPERATURE:Ambient: 140°F (60°C)
Media: 200°F (93°C)
MAX PRESSURE:100 PSIG (7 bar)
MAX OPERATING PRESSURE: Model S/SF:90 PSIG (6 bar)
Model M: 75, 90 PSIG (5, 6 bar)
Model L: 5, 10, 30, 75 PSIG (⅓, 0.7, 2, 5 bar)
PRESSURE DROP≤ 2” W.C. (5 mbar)
RECOMMENDED DIFF. PRESSURE:≥ 0.5 PSI; 14” W.C. (35 mbar)